A 6 pole dc armature has simplex lap connected 720 conductors, 3 turns per coil and 4 coil sides per slot. Determine the number of slots in the armature and state whether equalizers can be employed or not?

This question was previously asked in
ESE Electrical 2013 Paper 2: Official Paper
View all UPSC IES Papers >
  1. 60 slots and not possible
  2. 30 slots and possible
  3. 60 slots and possible
  4. 30 slots and not possible

Answer (Detailed Solution Below)

Option 3 : 60 slots and possible
Free
ST 1: UPSC ESE (IES) Civil - Building Materials
6.3 K Users
20 Questions 40 Marks 24 Mins

Detailed Solution

Download Solution PDF

\(\begin{array}{l} No\;of\;turns = \frac{{No\;of\;conductors}}{2} = \frac{{720}}{2} = 360\\ No\;of\;coils = \frac{{360}}{3} = 120 \end{array}\)

No of coil sides = 2 × no of coils = 2 × 120 = 240

No of slots = 240/4 = 60 slots

For employing equaliser ring equipotential pitch value should be integer i.e. 2C/P should be integer.

C = Number of coils

P = Number of poles

\(\frac{{2C}}{P} = \frac{{2 \times 120}}{6} = 40\)

Hence equaliser rings can be employed.